Battery Backup

Keep your MyControl Bathing System Operational During Power Outages.

APC350ESBE750G Features:

  •  Battery replacement without tools
  • Disconnected battery notification
  • LED status indicators
  • Master and controlled outlets
  • USB connectivity

The most popular desktop UPS in the world!

ABT offers information about the BE750G for reference purposes only. Consumer can select the battery back up of their choice as long as that choice meets or exceeds the requirements necessary to power MyControl fully in the vent of a power outage. ABT has determined the Back-UPS ES offers best value for protecting your MyControl Bathing System. It provides battery backup power that allowsES350backupsideview you to work through short and medium length power outages. It also safeguards your equipment from damaging surges and spikes that travel along your utility and phone lines. (Coax cable surge protection is also included on selected models.) Award-winning software automatically shuts down your Bathing System in the event of an extended power outage. Additional features like audible alarms, an LED status indicator, user replaceable battery, push-button circuit breakers and transformer-block spaced outlets make the Back-UPS ES the perfect unit to protect your Bathing System from the constant threat of power outages and potential damage. Visit a retailer of this and other battery back up units for purchase. Consumers can inquire about a particular battery back up suitability by calling ABT or asking an independent sales representative.

Technical Specifications:

Output

Output Power Capacity

450 Watts / 750 VA

Max Configurable Power

450 Watts / 750 VA

Nominal Output Voltage

120V

Output Frequency (sync to mains)

60Hz +/- 3 Hz

Waveform Type

Stepped approximation to a sinewave

Output Connections

(5) NEMA 5-15R (Battery Backup)

(5) NEMA 5-15R (Surge Protection)

Input

Nominal Input Voltage

120V

Input Frequency

50/60 Hz +/- 3 Hz (auto sensing)

Input Connections

NEMA 5-15P

Cord Length

6 feet (1.83 meters)

Input voltage range for main operations

88 – 139V

Batteries & Runtime

Battery Type

Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof

Typical recharge time

16 hour(s)

Replacement battery cartridge

RBC17

RBC™ Quantity

1

Typical Backup Time

at Half Load

11.3 minutes (225 Watts)

Typical Backup Time

at Full Load

2.3 minutes (200 Watts)

Runtime Chart

Back-UPS ES

Included Battery Modules

1

Efficiency in Battery Operation

83%

Maximum Battery Current at End of Discharge

55

Communications & Management

Control panel

LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault

Surge Protection and Filtering

Surge energy rating

355 Joules

Filtering

Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449

Dataline protection

RJ-45 Modem/Fax/DSL/ISDN/10-100 Base-T protection,Cable modem / Video protection

Physical

Maximum Height

3.48 inches (88 mm)

Maximum Width

7.09 inches (180 mm)

Maximum depth

13.49 inches (343 mm)

Net Weight

10.34 lbs. (4.70 kg)

Shipping Weight

12.54 lbs. (5.70 kg)

Shipping Height

5.94 inches (151 mm)

Shipping Width

10.16 inches (258 mm)

Shipping Depth

17.80 inches (452 mm)

Master Carton Units

2.00

Master Carton Dimensions (Length x Width x Height)

18 x 12 x 11 inches (465 x 312 x 278 mm)

Master Carton Weight

27.28 lbs. (12.40 kg)

Color

Black

SCC Codes

1073130425660 8

Environmental

Operating Environment

32 – 104 °F (0 – 40 °C)

Operating Relative Humidity

5 – 95%

Operating Elevation

0-10000 feet (0-3000 meters)

Storage Temperature

5 – 113 °F (-15 – 45 °C)

Storage Relative Humidity

5 – 95%

Storage Elevation

0-50000 feet (0-15000 meters)

Audible noise at 1 meter from surface of unit

45 dBA

Online Thermal Dissipation

14.00 BTU/hr

Conformance

Regulatory Approvals

FCC Part 15 Class B,FCC Part 68,NOM,UL 1778

Standard Warranty

3 years repair or replace

Equipment protection policy

Lifetime : $75000

**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.